Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 242
Filtrar
1.
Hernia ; 26(6): 1669-1678, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35536371

RESUMO

BACKGROUND: Because of the complexity of the intra-abdominal anatomy in the posterior approach, a longer learning curve has been observed in laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair. Consequently, automatic tools using artificial intelligence (AI) to monitor TAPP procedures and assess learning curves are required. The primary objective of this study was to establish a deep learning-based automated surgical phase recognition system for TAPP. A secondary objective was to investigate the relationship between surgical skills and phase duration. METHODS: This study enrolled 119 patients who underwent the TAPP procedure. The surgical videos were annotated (delineated in time) and split into seven surgical phases (preparation, peritoneal flap incision, peritoneal flap dissection, hernia dissection, mesh deployment, mesh fixation, peritoneal flap closure, and additional closure). An AI model was trained to automatically recognize surgical phases from videos. The relationship between phase duration and surgical skills were also evaluated. RESULTS: A fourfold cross-validation was used to assess the performance of the AI model. The accuracy was 88.81 and 85.82%, in unilateral and bilateral cases, respectively. In unilateral hernia cases, the duration of peritoneal incision (p = 0.003) and hernia dissection (p = 0.014) detected via AI were significantly shorter for experts than for trainees. CONCLUSION: An automated surgical phase recognition system was established for TAPP using deep learning with a high accuracy. Our AI-based system can be useful for the automatic monitoring of surgery progress, improving OR efficiency, evaluating surgical skills and video-based surgical education. Specific phase durations detected via the AI model were significantly associated with the surgeons' learning curve.


Assuntos
Hérnia Inguinal , Laparoscopia , Humanos , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Telas Cirúrgicas , Inteligência Artificial , Laparoscopia/métodos
2.
Br J Surg ; 107(13): 1780-1790, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32869868

RESUMO

BACKGROUND: A surgical approach preserving functional adrenal tissue allows biochemical cure while avoiding the need for lifelong steroid replacement. The aim of this experimental study was to evaluate the impact of intraoperative imaging during bilateral partial adrenalectomy on remnant perfusion and function. METHODS: Five pigs underwent bilateral posterior retroperitoneoscopic central adrenal gland division (9 divided glands, 1 undivided). Intraoperative perfusion assessment included computer-assisted quantitative fluorescence imaging, contrast-enhanced CT, confocal laser endomicroscopy (CLE) and local lactate sampling. Specimen analysis after completion adrenalectomy (10 adrenal glands) comprised mitochondrial activity and electron microscopy. RESULTS: Fluorescence signal intensity evolution over time was significantly lower in the cranial segment of each adrenal gland (mean(s.d.) 0·052(0·057) versus 0·133(0·057) change in intensity per s for cranial versus caudal parts respectively; P = 0·020). Concordantly, intraoperative CT in the portal phase demonstrated significantly lower contrast uptake in cranial segments (P = 0·031). In CLE, fluorescein contrast was observed in all caudal segments, but in only four of nine cranial segments (P = 0·035). Imaging findings favouring caudal perfusion were congruent, with significantly lower local capillary lactate levels caudally (mean(s.d.) 5·66(5·79) versus 11·58(6·53) mmol/l for caudal versus cranial parts respectively; P = 0·008). Electron microscopy showed more necrotic cells cranially (P = 0·031). There was no disparity in mitochondrial activity (respiratory rates, reactive oxygen species and hydrogen peroxide production) between the different segments. CONCLUSION: In a model of bilateral partial adrenalectomy, three intraoperative imaging modalities consistently discriminated between regular and reduced adrenal remnant perfusion. By avoiding circumferential dissection, mitochondrial function was preserved in each segment of the adrenal glands. Surgical relevance Preservation of adrenal tissue to maintain postoperative function is essential in bilateral and hereditary adrenal pathologies. There is interindividual variation in residual adrenocortical stress capacity, and the minimal functional remnant size is unknown. New intraoperative imaging technologies allow improved remnant size and perfusion assessment. Fluorescence imaging and contrast-enhanced intraoperative CT showed congruent results in evaluation of perfusion. Intraoperative imaging can help to visualize the remnant vascular supply in partial adrenalectomy. Intraoperative assessment of perfusion may foster maximal functional tissue preservation in bilateral adrenal pathologies and procedures.


ANTECEDENTES: Un abordaje quirúrgico que preserve la función del tejido suprarrenal permite lograr la curación bioquímica, a la vez que evita la necesidad de tratamiento sustitutivo con corticoides de por vida. El objetivo de este estudio experimental fue evaluar el impacto de las técnicas de imagen intraoperatorias en la suprarrenalectomía parcial (partial adrenalectomy, AE) bilateral sobre la perfusión y función del remanente glandular. MÉTODOS: Cinco cerdos fueron sometidos a una división bilateral central de la glándula suprarrenal por retroperitoneoscopia posterior (n = 9, 1 sin dividir). Durante la intervención, la evaluación de la perfusión incluyó la fluorescencia con cuantificación asistida por ordenador (Realidad Aumentada basada en la Fluorescencia, FLuorescence-based Enhanced Reality, FLER), tomografía computarizada (computed tomography, CT), endomicroscopia con laser confocal (confocal laser endomicroscopy, CLE) y un muestreo local de lactato. El análisis de la pieza quirúrgica tras completar la AE (n = 10) incluyó actividad mitocondrial y microscopia electrónica. RESULTADOS: La evolución de la intensidad de la señal de fluorescencia a lo largo del tiempo (ΔI/s) fue significativamente más baja en el segmento craneal de cada una de las glándulas (0,052 ± 0,057 craneal versus 0,133 ± 0,057 caudal, P = 0,02). De forma concordante, la CT intraoperatoria en la fase portal demostró una captación de contraste significativamente más baja en los segmentos craneales (P = 0,03). En la CLE, el contraste de fluoresceína se observó en todos los segmentos caudales, pero solo en el 44% de los segmentos craneales (P = 0,04). Los hallazgos obtenidos en las pruebas de imagen favorables a la perfusión caudal fueron congruentes con niveles significativamente más bajos de lactato capilar a nivel local (11,58 ± 6,53 mmol/L craneal versus 5,66 ± 5,79 mmol/L caudal, P = 0,008). A nivel craneal, la microscopia electrónica mostró más células necróticas (P = 0,03). La actividad mitocondrial (tasas de respiración, especies reactivas de oxígeno y producción de H2 O2 ) no mostraron disparidad entre los diferentes segmentos. CONCLUSIÓN: En un modelo de AE parcial bilateral, las tres modalidades de pruebas de imagen intraoperatorias podrían discriminar de forma consistente una perfusión regular y reducida del remanente suprarrenal. Al evitar una disección circunferencial, se preservó la función mitocondrial en cada segmento de las glándulas suprarrenales.


Assuntos
Glândulas Suprarrenais/irrigação sanguínea , Glândulas Suprarrenais/diagnóstico por imagem , Adrenalectomia/métodos , Cuidados Intraoperatórios/métodos , Glândulas Suprarrenais/fisiologia , Glândulas Suprarrenais/cirurgia , Animais , Biomarcadores/metabolismo , Feminino , Ácido Láctico/metabolismo , Masculino , Microscopia Confocal , Microscopia Eletrônica , Mitocôndrias/metabolismo , Modelos Animais , Imagem Óptica , Período Pós-Operatório , Sus scrofa , Tomografia Computadorizada por Raios X
3.
Colorectal Dis ; 22(11): 1749-1753, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32443182

RESUMO

AIM: Transanal total mesorectal excision is a promising novel sphincter-saving procedure for low rectal cancer. However, the transanal bottom-up dissection is associated with increased rates of iatrogenic urethral injuries. Near-infrared fluorescence (NIRF) imaging, given its deeper tissue penetration, has been explored in a limited number of studies for enhanced intra-operative urethral visualization. In this study, we explored the feasibility of a novel, ultrabright, biocompatible fluorescent polymer to coat urinary catheters for the purpose of intra-operative urethral visualization. METHODS: In an ex vivo experiment, using a near-infrared laparoscope, the fluorescent signal of a coated catheter (near-infrared coating of equipment, NICE) was qualitatively and quantitatively compared to the signal of indocyanine green (ICG)/Instillagel® mixtures and ICG-filled catheters at several concentrations. Also, in three male human torsos, using fluorescent urinary catheters, NIRF-guided perineal dissections and a transanal total mesorectal excision were performed. Intra-operative NIRF-based urethral visualization was performed systematically. RESULTS: During the qualitative and quantitative fluorescence signal assessment, NICE-coated catheters were clearly superior to the ICG-based solutions. In the cadaveric experiments, enhanced urethral visualization was possible even at early stages of dissection, when the organ was covered by several tissue layers. CONCLUSIONS: NICE-coated catheters represent a promising potential to allow for NIRF-based intra-operative urethral visualization.


Assuntos
Imagem Óptica , Uretra , Cadáver , Humanos , Verde de Indocianina , Masculino , Períneo/cirurgia , Uretra/diagnóstico por imagem , Uretra/cirurgia
4.
Hernia ; 23(6): 1175-1185, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31312941

RESUMO

PURPOSE: To evaluate the feasibility and safety of a new percutaneous image-guided surgery technique to simulate a hernia repair using hydrogel. MATERIALS AND METHODS: A comparative prospective study was conducted in animals, with survival. Five pigs without any hernias were used. A hydrogel was injected at a site corresponding to the preperitoneal inguinal region. This procedure was performed bilaterally. An image-guided needle (ultrasound and computed tomography) was used, through which the material was injected. After survival, the local and systemic inflammatory reaction generated by the new material, was studied. RESULTS: All animals survived the procedure. No hemorrhagic or infectious complications were reported. The solidification of the material occurred as expected. In eight out of ten cases, the material was found in the planned site. No systemic inflammatory reaction secondary to the administration of hydrogel was reported. The adhesion of the material to surrounding tissues was satisfactory. CONCLUSION: The introduction of a liquid material which solidifies after injection in a short time (hydrogel) using a needle is feasible. The combined CT-scan and US image guidance allows for the percutaneous placement of the needle in the required location. The introduced hydrogel remains in this space, corresponding to the inguinal region, without moving. The placed hydrogel compresses the posterior wall composed of the transversalis fascia, supporting the potential use of hydrogel for hernia defects.


Assuntos
Materiais Biocompatíveis/administração & dosagem , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Hidrogéis/administração & dosagem , Cirurgia Assistida por Computador/métodos , Parede Abdominal/diagnóstico por imagem , Animais , Fáscia , Estudos de Viabilidade , Feminino , Virilha/diagnóstico por imagem , Hérnia Inguinal/diagnóstico por imagem , Masculino , Estudos Prospectivos , Suínos , Tomografia Computadorizada por Raios X , Ultrassonografia
5.
Rev. med. Rosario ; 85(1): 34-34, ene.-abr. 2019.
Artigo em Inglês | LILACS | ID: biblio-1053022

RESUMO

BACKGROUND: When a major hepatic resection is necessary, sometimes the future liver remnant is not enough to maintain sufficient liver function and patients are more likely to develop liver failure after surgery. AIM: To test the hypothesis that performing a percutaneous radiofrecuency liver partition plus percutaneous portal vein embolization (PRALPPS) for stage hepatectomy in pigs is feasible. METHODS: Four pigs (Sus scrofa domesticus) both sexes with weights between 25 to 35 kg underwent percutaneous portal vein embolization with coils of the left portal vein. By contrasted CT, the difference between the liver parenchyma corresponding to the embolized zone and the normal one was identified. Immediately, using the fusion of images between ultrasound and CT as a guide, radiofrequency needles were placed percutaneouslyand then ablated until the liver partition was complete. Finally, hepatectomy was completed with a laparoscopic approach. RESULTS: All animals have survived the procedures, with no reported complications. The successful portal embolization process was confirmed both by portography and CT. In the macroscopic analysis of the pieces, the depth of the ablation was analyzed. The hepatic hilum was respected. On the other hand, the correct position of the embolization material on the left portal vein could be also observed. CONCLUSION: "Percutaneous radiofrequency assisted liver partition with portal vein embolization" (PRALLPS) is a feasible procedure (AU)


Assuntos
Animais , Masculino , Feminino , Veia Porta , Ablação por Cateter , Embolização Terapêutica , Hepatectomia/métodos , Suínos , Ablação por Radiofrequência
6.
J Visc Surg ; 156(5): 381-386, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30885707

RESUMO

INTRODUCTION: Common bile duct lithiasis after Roux-en-Y gastric bypass (RYGB) or upper gastrointestinal stenosis has become a challenging problem nowadays, especially as obesity surgery is increasing. In this study, we assess the feasibility and performance of laparoscopy-assisted transgastric endoscopic retrograde cholangiopancreatography (LAERCP) and describe its technique. METHODS: A retrospective review of a prospectively collected database of consecutive patients undergoing a LAERCP between February 2014 and May 2015 was performed at a single institution. Indications were common bile duct lithiasis associated with acute or past episodes of cholangitis and pancreatitis. Endoscopic access to the gastric remnant was obtained laparoscopically. RESULTS: In total 5 cases were identified. Four of them had undergone a RYGB and one of them presented a benign esophageal peptic stenosis, not allowing peroral gastric access. Biliary cannulation using LAERCP associated with sphincterotomy and stone extraction was successfully achieved in all patients. Mean duration of the entire procedure was 134minutes (range: 66-200min). No early major complications were observed and the mean postoperative hospital stay was 4 days (range: 2-5 days). CONCLUSIONS: LAERCP is a safe and successful procedure for the treatment of common bile duct lithiasis when conventional biliary access is not feasible, notably after RYGB. Larger trials still need to be performed to evaluate efficacy, technical success, and complications related to this technique.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/métodos , Cálculos Biliares/terapia , Laparoscopia , Esfinterotomia Endoscópica/métodos , Adulto , Feminino , Seguimentos , Cálculos Biliares/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
7.
Tech Coloproctol ; 23(1): 53-63, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30656579

RESUMO

BACKGROUND: Real-time stereotactic navigation for transanal total mesorectal excision has been demonstrated to be feasible in small pilot series using laparoscopic techniques. The possibility of real-time stereotactic navigation coupled with robotics has not been previously explored in a clinical setting. METHODS: After pre-clinical assessment, and configuration of a robotic-assisted navigational system, two patients with locally advanced rectal cancer were selected for enrollment into a pilot study designed to assess the feasibility of navigation coupled with the robotic da Vinci Xi platform via TilePro interface. In one case, fluorescence-guided surgery was also used as an adjunct for structure localization, with local administration of indocyanine green into the ureters and at the tumor site. RESULTS: Each operation was successfully completed with a robotic-assisted approach; image-guided navigation provided computed accuracy of ± 4.5 to 4.6 mm. The principle limitation encountered was navigation signal dropout due to temporary loss of direct line-of-sight with the navigational system's infrared camera. Subjectively, the aid of navigation assisted the operating surgeon in identifying critical anatomical planes. The combination of fluorescence with image-guided surgery further augmented the surgeon's perception of the operative field. CONCLUSIONS: The combination of stereotactic navigation and robotic surgery is feasible, although some limitations and technical challenges were observed. For complex surgery, the addition of navigation to robotics can improve surgical precision. This will likely represent the next step in the evolution of robotics and in the development of digital surgery.


Assuntos
Laparoscopia/métodos , Neuronavegação/métodos , Neoplasias Retais/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Técnicas Estereotáxicas , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Ilustração Médica , Projetos Piloto
8.
Dis Esophagus ; 32(2)2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30295748

RESUMO

Flexible endoscopy has evolved to the point that it includes many endoluminal procedures that once required open or laparoscopic surgery, for instance, antireflux surgery, pyloromyotomy, mucosal and submucosal tumor resections, and even full-thickness resection. However, these procedures remain technically demanding due to flexible technology issues: difficult imaging, limited energy devices, lack of staplers, unsatisfactory suturing abilities, and so on. Transgastric laparoscopy or hybrid laparoscopy/flex endoscopy has been described for almost two decades as an alternative to a pure endoluminal approach, mainly for pancreatic pseudocyst drainage and full-thickness and mucosal resection of various lesions. The approach has never been widely adopted mostly due to cumbersome and difficult to maintain methods of gastric access. We propose to expand the indications of transgastric laparoscopy by using novel endoscopically placed ports to replicate endoscopic procedures particularly in the difficult to access proximal stomach such as endoluminal antireflux surgery. Under general anesthesia, five female pigs (mean weight: 27.6 kg) had endoscopic placement of 3, 5 mm intragastric ports (Endo-TAGSS, Leakwood KS, USA) using a technique similar to percutaneous endoscopic gastrostomy. A 5-mm laparoscope was used for visualization. Laparoendoscopic-assisted plication of the gastroesophageal junction (GEJ) was performed using 3-0 interrupted sutures (Polysorb®, Covidien, Mansfield, MA, USA). A functional lumen imagine probe (EndoFLIP®, Crospon, Inc., Galway, Ireland) was used to measure diameter, cross sectional area (CSA), distensibility, and compliance of GEJ before and after intervention. Once the TAGSS ports were removed, the gastrotomies were closed by using endoscopic over-the-scope clips. At the end of the procedure, animals were euthanized. Five laparoendoscopic-assisted endoluminal plications were performed. The mean operative time was 65.6 min (Endoscopic evaluation: 3.2 min, TAGSS Insertion: 11 min, EndoFLIP evaluation + GEJ Plication: 43.25 min, gastric wall closure: 15 minutes). In all cases, this technique was effective and allowed to achieve an adequate GEJ plication by endoscopic grading and EndoFLIP measurements. Median pre-plication GEJ diameter (D) and median pre-plication GEJ cross-sectional area (CSA) were 11.42 mm (8.6-13.6 mm) and 104.8 mm2 (58-146 mm2). After the procedure, these values were decreased to 6.14 mm (5.7-6.6 mm) and 29.8 mm2 (25-34 mm2) respectively (p = 0.0079). Median pre-plication distensibility (d) and compliance (C) were 7.87 mm2/mmHg (2.4-22.69 mm2/mmHg) and 190.56 mm3/mmHg (70.9-502.8 mm3/mmHg). After the procedure, these values decreased to 1.5 mm2/mmHg (0.7-2.2 mm2/mmHg) and 52.17 mm3/mmHg (21.9-98.7 mm3/mmHg) respectively (p = 0.0317). No intraoperative events were observed. Endoscopically, all valves were felt to be transitioned from a Hill grade 3 (normal state for the animal model) to a Hill grade 1 at the procedure completion. A hybrid laparoendoscopic approach is a feasible alternative for performing intragastric procedures with the assistance of conventional laparoscopic instruments; especially in cases where the intervention location limits the access to standard endoscopy or where endoscopic technology is inadequate. Further evaluation is planned in survival models and clinical trials.


Assuntos
Endoscopia Gastrointestinal/métodos , Junção Esofagogástrica/cirurgia , Laparoscopia/métodos , Animais , Endoscopia Gastrointestinal/instrumentação , Feminino , Gastrostomia/instrumentação , Gastrostomia/métodos , Humanos , Modelos Animais , Duração da Cirurgia , Instrumentos Cirúrgicos , Técnicas de Sutura/instrumentação , Suínos
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 162-165, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31945869

RESUMO

The treatment of choice for the unresectable cholangiocarcinoma is based on biliary decompression procedures. Despite stent placement is the standard of care, it is related to well-known complications. Hence, alternative techniques were proposed. Ideally, they should guarantee an adequate intraductal disobstruction, without injuring the surrounding tissues.This pre-clinical study aims to investigate the thermal effects of the laser ablation (LA) in the biliary tree, in terms of intraductal and surrounding tissue temperature achieved with different laser settings. The common bile ducts (in their upper and lower portions) of two pigs were ablated for 6 minutes with a diode laser at 3 W and 5 W. A custom-made laser applicator was used to obtain a circumferential ablation within the ducts. The intraductal temperature (Tid) was monitored by means of a fiber Bragg grating (FBG) sensor, while an infrared thermal camera monitored the T distribution in the surrounding tissues (Tsup). A maximum T difference of 65 °C and 57 °C was evidenced between the two power settings for the Tid measured in the upper and lower ducts, respectively. The mean difference between Tid and the averaged Tsup values was evaluated. At 5 W, a difference of 37±3 °C and 44±10 °C were obtained for the upper and lower ducts, respectively. At 3 W, a T difference of 2±1 °C was obtained for the upper biliary duct, while a difference of 8±1 °C was documented for the lower duct. Based on the results obtained in this preliminary study, the possibility to equip the laser probe with temperature sensor can improve the control and the safety of the procedure; this solution will guarantee the monitoring of the treatment while preserving the lumen and the surrounding structures.


Assuntos
Ductos Biliares , Terapia a Laser , Animais , Lasers Semicondutores , Suínos , Temperatura
10.
Surg Endosc ; 32(8): 3582-3591, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29435745

RESUMO

BACKGROUND: Long-term morbidity after multimodal treatment for rectal cancer is suggested to be mainly made up by nerve-injury-related dysfunctions. Stereotactic navigation for rectal surgery was shown to be feasible and will be facilitated by highlighting structures at risk of iatrogenic damage. The aim of this study was to investigate the ability to make a 3D map of the pelvic nerves with magnetic resonance imaging (MRI). METHODS: A systematic review was performed to identify a main positional reference for each pelvic nerve and plexus. The nerves were manually delineated in 20 volunteers who were scanned with a 3-T MRI. The nerve identifiability rate and the likelihood of nerve identification correctness were determined. RESULTS: The analysis included 61 studies on pelvic nerve anatomy. A main positional reference was defined for each nerve. On MRI, the sacral nerves, the lumbosacral plexus, and the obturator nerve could be identified bilaterally in all volunteers. The sympathetic trunk could be identified in 19 of 20 volunteers bilaterally (95%). The superior hypogastric plexus, the hypogastric nerve, and the inferior hypogastric plexus could be identified bilaterally in 14 (70%), 16 (80%), and 14 (70%) of the 20 volunteers, respectively. The pudendal nerve could be identified in 17 (85%) volunteers on the right side and in 13 (65%) volunteers on the left side. The levator ani nerve could be identified in only a few volunteers. Except for the levator ani nerve, the radiologist and the anatomist agreed that the delineated nerve depicted the correct nerve in 100% of the cases. CONCLUSION: Pelvic nerves at risk of injury are usually visible on high-resolution MRI with dedicated scanning protocols. A specific knowledge of their course and its application in stereotactic navigation is suggested to improve quality of life by decreasing the likelihood of nerve injury.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório/métodos , Plexo Hipogástrico/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Diafragma da Pelve/cirurgia , Neoplasias Retais/cirurgia , Cirurgia Assistida por Computador/métodos , Humanos , Diafragma da Pelve/diagnóstico por imagem , Diafragma da Pelve/inervação , Neoplasias Retais/diagnóstico
11.
Surg Endosc ; 32(6): 2713-2720, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29214516

RESUMO

BACKGROUND: Stereotactic navigation could improve the quality of surgery for rectal cancer. Critical challenges related to soft tissue stereotactic pelvic navigation include the potential difference in patient anatomy between intraoperative lithotomy and preoperative supine position for imaging. The objective of this study was to determine the difference in patient anatomy, sacral tilt, and skin fiducial position between these different patient positions and to investigate the feasibility and optimal set-up for stereotactic pelvic navigation. METHODS: Four consecutive human anatomical specimens were submitted to repeated CT-scans in a supine and several degrees of lithotomy position. Patient anatomy, sacral tilt, and skin fiducial position were compared by means of an image computing platform. In two specimens, a 10-degree wedge was introduced to reduce the natural tilt of the sacrum during the shift from supine to lithotomy position. A simulation of laparoscopic and transanal surgical procedures was performed to assess the accuracy of the stereotactic navigation. RESULTS: An up-to-supracentimetric change in patient anatomy was noted between different patient positions. This observation was minimized through the application of a wedge. When switching from supine to another position, sacral retroversion occurred independent of the use of a wedge. There was considerable skin fiducial motion between different positions. Accurate stereotactic navigation was obtained with the least registration error (1.9 mm) when the position of the anatomical specimen was registered in a supine position with straight legs, without pneumoperitoneum, using a conventional CT-scan with an identical specimen positioning. CONCLUSION: The change in patient anatomy is small during the sacral tilt induced by positional changes when using a 10-degree wedge, allowing for an accurate stereotactic surgical navigation. This opens up new promising opportunities to increase the quality of surgery for rectal cancer cases where it is difficult or impossible to identify and dissect along the anatomical planes.


Assuntos
Imageamento Tridimensional , Laparoscopia/métodos , Pelve/cirurgia , Neoplasias Retais/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Cadáver , Humanos , Masculino , Pelve/diagnóstico por imagem , Postura , Neoplasias Retais/diagnóstico
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 873-876, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29060011

RESUMO

Thermal treatments are a valid clinical option in the management of several solid tumors. The difficulties to perform an accurate prediction improve the selectivity of the treatment effects represent the main hurdles in the spread of these techniques. Among other solutions, thermometric techniques are gaining acceptance in monitoring the effects of thermal treatments because they provide a clear end-point to obtain the complete removal of cancer without damaging the surrounding healthy tissue. This paper proposes a custom needle-like probe made of carbon fibers to embed seven fiber Bragg grating (FBG) sensors. This tool aims at a multiple points monitoring the tissue temperature during the thermal procedures, streamlining the FBG sensors insertion within the organ. After the description of the probe manufacturing, we reported the calibration of the seven sensors embedded within the probe, their step response, and the feasibility assessment of the probe for temperature monitoring during laser ablation on animal model (both in vivo and ex vivo). Results show that the proposed probe is easily maneuverable by the clinician, the sensors have a linear response with the temperature and a short step response; moreover, the probe allows measuring the temperature in seven points of the tissue; finally, it can be used during CTand MR-guided procedures without causing any artifact to the images. Thanks to these features the probe may be an useful solution to improve the safety and the outcomes of minimally invasive thermal ablation procedures, so to spread these procedures in the clinical field.


Assuntos
Temperatura , Animais , Carbono , Fibra de Carbono , Tecnologia de Fibra Óptica , Hipertermia Induzida , Termômetros
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 4533-4536, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29060905

RESUMO

Endoscopic submucosal dissection (ESD) is a minimally invasive technique allowing for the removal of early gastrointestinal (GI) tumors, widely considered as a valid alternative to conventional surgery. However, ESD is technically demanding, and potentially severe complications, such as bleeding and perforation, may occur. Energy-based techniques (e.g., radiofrequency ablation) might offer a potential alternative to ESD. However, their use mandates the ability to predict the damage induced and to identify a "signature" of the complete ablation, without the need for a physical specimen. Ideally, an energy-based procedure should be tunable in order to limit the ablation to the superficial layers, namely mucosa (M) and submucosa (SM), without injuring the muscularis propria (MP), thereby minimizing GI perforation. This experimental study aims to investigate thermal damage induced by Nd:YAG laser on the gastric wall, at different laser settings such as power (P) and time (t). Laser ablation was performed on the stomach wall of 6 Wistar rats. Two powers (2.5W and 1.0W) and 3 exposure times (12s, 6s and 2s) were tested, for a total of 30 ablations. Histological analysis allowed to assess thermal damage, in terms of damage depth (DD) and identification of involved layers. The ratio (R) between DD and the total depth (TD) of target layers (M+SM) was used as an index to evaluate the effectiveness of laser settings. At P=2.5W, MP was damaged (R>1) in the majority of cases (11/15). At P=1.0W, MP was preserved in all tests (R<;1), and rarely (4/15) did the damage reach the whole SM (R=1). Histopathological analysis evidenced that tissue damage was strongly related to the variable tissue thickness. These preliminary results seem to support the fact that endoscopic tunable laser ablation is feasible with a consistent damage/power correlation. Further tests are required to optimize the settings for applications on early GI tumors.


Assuntos
Terapia a Laser , Animais , Neoplasias Gastrointestinais , Lasers de Estado Sólido , Ratos , Ratos Wistar
14.
Br J Surg ; 104(3): 248-256, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27901287

RESUMO

BACKGROUND: Robust data on quality of life (QoL) after different techniques of bariatric surgery are sparse. This RCT compared excess weight loss (EWL) and QoL after sleeve gastrectomy versus Roux-en-Y gastric bypass (RYGB). METHODS: Obese patients were assigned randomly to RYGB or sleeve gastrectomy. The primary outcome measure was EWL. Secondary outcomes included QoL, co-morbidity, adverse events, vitamin and glycolipid status. QoL was assessed before and annually after surgery, using the Moorehead-Ardelt Quality of Life Questionnaire II (M-A-QoLQII) and Gastrointestinal Quality of Life Index (GIQLI). RESULTS: One hundred patients were enrolled, 45 in the RYGB group and 55 in the sleeve gastrectomy group. Mean postoperative EWL at 1, 2, 3 and 5 years was 80·4, 79·8, 83·0 and 74·8 per cent respectively after RYGB, and 83·0, 77·8, 66·3 and 65·1 per cent after sleeve gastrectomy (P = 0·017). Mean M-A-QoLQII score before surgery and at 1, 2, 3 and 5 years after operation was 0·5, 1·6, 1·7, 2·1 and 1·4 respectively after RYGB, and 0·3, 1·7, 1·5, 1·5 and 1·2 after sleeve gastrectomy. Mean GIQLI score before and at 1, 2, 3, 5 years after RYGB was 96·4, 113·8, 113·3, 113·4, 111·7, compared with 90·7, 113·9, 114·5, 113·1 and 113·0 for sleeve gastrectomy. The improvement was significant compared with preoperative values (P < 0·001 for M-A-QoLQII and GIQLI), with no difference between groups (P = 0·418 and P = 0·323 respectively). RYGB resulted in higher readmission rates (P = 0·002) and length of hospital stay (P = 0·006) than sleeve gastrectomy. CONCLUSION: RYGB and sleeve gastrectomy resulted in equivalent, long-standing QoL improvement. RYGB resulted in more stable weight loss but was associated with higher readmission rates. Registration number: NCT02475590.


Assuntos
Gastrectomia , Derivação Gástrica , Obesidade Mórbida/cirurgia , Qualidade de Vida , Redução de Peso , Adolescente , Adulto , Feminino , Seguimentos , Gastrectomia/métodos , Derivação Gástrica/métodos , Indicadores Básicos de Saúde , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Resultado do Tratamento , Adulto Jovem
15.
Ann Surg Oncol ; 23(Suppl 5): 968, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27459980

RESUMO

BACKGROUND: An expert consensus meeting had defined the standard lymphadenectomy during pancreatoduodenectomy for an adenocarcinoma of the head of the pancreas. There is a controversy regarding the possibility to perform this optimal lymphadenectomy by minimally invasive approach. PATIENTS: The patient was a 68-year-old man with the diagnosis of an adenocarcinoma of the head of the pancreas. The 3D reconstructions evidenced the existence of a right hepatic artery. TECHNIQUE: The patient was positioned in the French position with the assistant between the legs and the robot at the head. Five trocars were used; the camera was introduced through the umbilicus trocar. The operation began with a peritoneal and liver exploration, and with an inter-aortico-caval picking. Because lymph nodes were noninvaded, pancreatoduodenectomy was decided with the first dissection of the superior mesenteric artery helped with a hanging maneuver. The right hepatic artery was dissected. Each structure of the hepatic pedicle was skeletonized. The camera was switched to the right side. The first jejunal loop was divided with a stapler. The specimen was totally mobilized en bloc, freed from the portal vascular axis with a dissection of the right border of the coeliac trunk. The pancreas was divided. At the end of the dissection, the different arterial and venous structures were skeletonized with a resection of the lymph node group 5-6-8a-12a,b,c-13a,b-14a,b-17a,b. Pathology confirmed R0 resection for a well-differentiated pancreatic adenocarcinoma graded pT3N1 (5/20). CONCLUSIONS: Robotic pancreatoduodenectomy could be performed with an optimal standard lymphadenectomy as recommended by the expert consensus.


Assuntos
Adenocarcinoma/cirurgia , Excisão de Linfonodo/métodos , Artéria Mesentérica Superior/cirurgia , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Dissecação , Humanos , Masculino
16.
J Visc Surg ; 153(5): 353-359, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27185566

RESUMO

Over recent years, minimally invasive pancreatic resections have increasingly been reported in the literature. Even though pancreatic surgery is still considered a challenge for surgeons due to its technical difficulties and high morbidity, the development and spread of robotic surgery has highlighted a new interest, which has induced a rapid spread of robotic approaches for pancreatic resections. This study presents a systematic review of the literature regarding robotic pancreaticoduodenectomy and distal pancreatectomy in order to assess the safety and feasibility of robotic pancreatic resection.


Assuntos
Pancreatectomia/métodos , Pancreatopatias/cirurgia , Pancreaticoduodenectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Humanos
18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 5174-5179, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269431

RESUMO

In this work, we investigated the temperature increment experienced by biological tissue during radiofrequency ablation (RFA). The measurements were performed by using two custom-made thermal probes based on fiber optic sensors (fiber Bragg gratings, FBGs). The two probes embed a total of 9 FBGs. Experiments were performed during RFA of an ex vivo healthy porcine liver. The RFA heating module was equipped with 5 thermocouples. Results show that the temperature increment close to the applicator (i.e., 0.6 cm-0.7 cm) reaches the temperature which is set as a target on the RFA module (i.e., approximately 100 °C). The distance from the applicator also has an impact on the dynamics of the heating phenomenon: at short distances the tissue temperature reaches a steady state condition after a few minutes, on the other hand the sensors placed at a distance ≥2cm did not reach the steady-state conditions during the 14-minute procedure. The multipoint temperature monitoring, which uses sensors at several distances from the applicator, can provide useful information regarding the boundary of damaged volume. This approach can be combined with the monitoring temperature system embedded in the heating equipment, to better control the damaged volume, and to improve the treatment outcomes.


Assuntos
Ablação por Cateter/instrumentação , Fígado/cirurgia , Monitorização Intraoperatória/instrumentação , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Animais , Tecnologia de Fibra Óptica/instrumentação , Suínos , Temperatura
19.
Tech Coloproctol ; 20(1): 11-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26611358

RESUMO

Transanal total mesorectal excision (TME) is an emerging minimally invasive approach to rectal cancer, with encouraging preliminary results. However, the new surgical anatomy of the bottom-up approach complicates surgical understanding and increases the risks of inadvertent injuries to crucial anatomical structures, including nerves. Key elements to improve the safety and stimulate interest in such a complex technique might be robotics and image guidance, to enhance the level of precision. In this editorial, some of the technologies that could be used for precision TME are outlined, in light of the experience of our Institute for Image-Guided Surgery.


Assuntos
Colectomia/métodos , Imageamento Tridimensional/métodos , Medicina de Precisão/métodos , Neoplasias Retais/cirurgia , Reto/cirurgia , Cirurgia Endoscópica Transanal/métodos , Canal Anal/cirurgia , Humanos , Ilustração Médica , Procedimentos Cirúrgicos Robóticos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA